Special Projects

When it comes to safe equipment or processes, having a customized solution in electrical cables can be fundamental to the success of your company, whether to meet your technical needs or simply because of a more appropriate layout or visual. Pan Electric is specially equipped to develop the solution you need.

Pancontrole AA

They can be suspended or used in places that should withstand any tensile loads.

Materials:

Central chordae: galvanized wire cable of 1.55 mm in diameter;

Conductor: bare copper electrolytic wires, annealed, stranding class 5;

Insulation: thermoplastic polyvinyl chloride compound (PVC);

Coverage: thermoplastic polyvinyl chloride compound (PVC).

Specifications:

Identification of conductors: black numbered or color veins (on request).

Applicable standards: NBR 7289

DOWNLOAD PDF

Properties:

Working temperature: thermal stability up to 70 °C

Moderate resistance to acids bases

Flame resistant

Good resistance to oils

Great tensile strength by supporting up to 220Kg

Isolation voltage 500V to sections of 0.5 to 1mm ² and 1KV to sections of 1.5 to 10mm ²

PANSOLAR 0,9/1,8KV

For applications in photovoltaic power supply systems indoors or outdoors.

Materials:
Conductor: Tinned copper wires, class 5 stranding.
Insulation: Non-halogenated thermosetting compound at 90ºC. Coverage: Non-halogenated thermosetting compound 90ºC flame-retardant.

Specifications:
Applicable Standard: EN 50618 and NBR 16612
DOWNLOAD PDF

Properties

Maximum ambient temperature allowed in continuous use: from –15 to 90°C. Aging tests guarantee a durability greater than 25 years under normal conditions of use. · Maximum permissible conductor operating temperature: + 120°C for a maximum of 20,000 h and ambient at 90°C; · Moisture, heat, weather and UV resistant; · Insulation voltage:0.9/1.8kV · High temperature pressure resistant; · Resistant to dynamic penetration; · Acid and alkaline resistance; · Flame resistant · Low smoke, toxicity and corrosiveness;


Panerg EPR/PVC

Used for fixed installations, in generating and distribution circuits of electricity at Voltages of 0.6/1KV.

Materials:

Conductor: tinned or annealed electrolytic bare copper, stranding class 4

Insulation: thermosetting ethylene propylene rubber compound (EPR)

Coverage: thermoplastic polyvinyl chloride compound (PVC)

These cables may have mechanical frame in galvanized steel, where provided.

Specifications:

Identification of conductors: black, numbered or color veins (on request).

Applicable Standards: NBR 7286

Packaging: Coil


DOWNLOAD PDF

Properties:

Working temperature: thermal stability up to 90 °C

Good resistance to oils

Flame resistant

Moderate resistance to acids and bases

KMAT 400ºC 1KV

For the use in environments or equipment with high temperatures such as heaters, ovens, injection molding and extruders, among others.

Materials:

Conductor: bare electrolytic copper, nickel-plated copper*,pure nyckel wires*, stranding class 4.

Insulation: Polyimide and Mica Tape

Cover: white glass fiber braid with red stripe.

Specifications:

EPAN 37 400°C e UL 5571 200°C

DOWNLOAD PDF

Properties:

Working temperature: thermal stability up to 400 ºC

Flexible at temperatures below 0 °C

Excellent balance of electrical, chemical and thermal properties.

Highly resistant to radiation

In addition to providing better properties and mechanical characteristics, the interpolation of the two strands confers greater Isolation voltage (1KV).

Flame resistant

Should be applied in dry environments.

Recommended for fixed use

Section: 1.0 to 10.0 mm ² (remaining sections on request).

*These products will be provided on request

Pansil 200ºC 0,6/1KV

Used in electric resistances, heaters, portable devices connections and where conductors must be resistant to heat at Voltages of 0.6 / 1KV.

Materials:

Conductor: bare electrolytic copper wires, annealed, stranding class 4.

Insulation: cross-linked silicone rubber for 200 º C

Coverage: cross-linked silicone rubber for 200 º C

External Braid: glass fiber wires braid (optional).

These cables can have non-hygroscopic polyester tape and braided shielding copper wire, where provided.

Specifications:

Identification of Conductors: white, numbered or colored veins (upon request).

Applicable Standards: EPAN 05 (Pan Electric)

Packaging: Coil

DOWNLOAD PDF

Properties:

Working temperature: thermal stability up to 200 ºC

Flexible at temperatures below 0 °C (up to -70°C)

Silicone provides good resistance to acids, grease and moisture.

Resistance to ozone

Braided fiberglass: provides greater mechanical strength and assists in thermal protection.

Panerg XLPE/PVC

Used for fixed installations, in generating circuits and distribution of electricity at voltages of 0.6 / 1KV.

Materials:

Conductor: bare or tinned electrolytic copper wires, annealed, stranding class 4

Insulation: cross-linked polyethylene (XLPE).

Coverage: thermoplastic polyvinyl chloride compound (PVC).

These cables may have braided shielding wire or copper tape and mechanical frame in galvanized steel, where provided.

Specifications:

Identification of conductors: black numbered or color veins (on request).

Applicable Standards: NBR 7287

Packaging: Coil

DOWNLOAD PDF

Properties:

Working temperature: thermal stability up to 90 °C

Good resistance to oils

Flame resistant

Moderate resistance to acids and bases

Panerg XLPE/PVC

Used for fixed installations, in generating circuits and distribution of electricity at voltages of 0.6 / 1KV.

Materials:

Conductor: bare or tinned electrolytic copper wires, annealed, stranding class 4

Insulation: cross-linked polyethylene (XLPE).

Coverage: thermoplastic polyvinyl chloride compound (PVC).

These cables may have braided shielding wire or copper tape and mechanical frame in galvanized steel, where provided.

Specifications:

Identification of conductors: black numbered or color veins (on request).

Applicable Standards: NBR 7287

Packaging: Coil

DOWNLOAD PDF

Properties:

Working temperature: thermal stability up to 90 °C

Good resistance to oils

Flame resistant

Moderate resistance to acids and bases

Paneger EPR/EPR

Used for fixed installations, in generating circuits and distribution of electricity at voltages of 0.6 / 1KV.

Materials:

Conductor: bare or tinned electrolytic copper wires, annealed, stranding class 4.

Insulation: thermosetting ethylene propylene rubber compound (EPR)

Coverage: thermosetting ethylene propylene rubber compound (EPR)

These cables may have braided shielding wire or copper tape and mechanical frame in galvanized steel, where provided.

Specifications:

Identification of conductors: black numbered or color veins (on request).

Applicable Standards: NBR 7286

Packaging: Coil

DOWNLOAD PDF

Properties:

Working temperature: thermal stability up to 90 °C

Excellent resistance to ozone, weathering and water

UV Resistance

Flame resistant

Pancontrole EPR/PVC

Used in control panels, control and signaling equipment.

Materials:

Conductor: bare or tinned electrolytic copper wires, annealed, stranding class 4.

Insulation: thermosetting ethylene propylene rubber compound (EPR)

Separator: non-hygroscopic tape (optional) polyester.

Shielding: tape, spiral, copper wire braid or aluminized polyester tape + drain cable (optional).

Coverage: thermoplastic polyvinyl chloride compound (PVC).

These cables may have mechanical frame in galvanized steel, where provided.

Specifications:

Identification of conductors: black, numbered or color veins (on request).

Applicable Standards: NBR 7290.

Packaging: Coil.

DOWNLOAD PDF

Properties:

Working temperature: thermal stability up to 90 °C

Good resistance to oils

Flame resistant

Moderate resistance to acids and bases

Isolation voltage: 500V to sections of 0.5 to 1.0 mm² and 1KV to sections 1.5 to 10.0 mm²

Pansinal

They are primarily intended for the use in electronic instrumentation of industrial plant in general and in particular for the chemical and petrochemical industry.

Materials:

Conductor: bare or tinned electrolytic copper wires, annealed, stranding class 2.

Insulation: Compound thermoplastic polyvinyl chloride (PVC) for 70, 105 °C or polyethylene.

Shielding: aluminized polyester tape with tinned copper drain cable of 0.5 mm², minimum overlap of 25% or braiding of copper wires

Coverage: thermoplastic polyvinyl chloride compound (PVC) to 70 °C or 105 °C

Formation: pairs and ternas

Cables may have mechanical frame in galvanized steel, where provided.

Specifications:

Identification of conductors

Veins: black / white / numbered: for pairs

Veins: black / white / red / numbered: for ternas

Applicable Standards: NBR 10300.

DOWNLOAD PDF

Properties:

Working temperature: thermal stability up to 70 ºC and 105 ºC

Manufactured for Isolation voltage: 150/300V in sections of 0.5 to 2.5 mm².

Flame resistant

Good resistance to oils

Moderate resistance to acids and bases

Pancontrole PVC/PVC (Pancontrol PVC/PVC)

Used in control panels, control and signaling equipment.

Materials:

Conductor: tinned or annealed electrolytic bare copper, stranding class 4.

Insulation: thermoplastic polyvinyl chloride compound (PVC)

Separator: non-hygroscopic polyester tape (optional)

Shielding: tape, braided copper wires or aluminized polyester tape + drain cable (optional).

Coverage: thermoplastic polyvinyl chloride compound (PVC).

These cables may have mechanical frame in galvanized steel, where provided.

Specifications:

Identifier of conductors: black, numbered or color veins (on request).

Applicable Standards: NBR 7289

Packaging: Coil

DOWNLOAD PDF

Properties:

Isolation voltage: 500V in sections of 0.5 to 1mm ² and 1KV in sections of 1.5 to 10mm².

Working temperature: thermal stability up to 70 °C

Good resistance to oils

Flame resistant

Moderate resistance to acids and bases