MOBILE CABLES

Superflexible power, control and instrumentation cables for occasional mobile use or in constant motion, resistant to abrasion and traction for cases where the cable suffers drag and / or friction from the floor.

W-M 750V


Used for connections with external power sources of heavy mobile mining equipment, metallurgy, port and other activities.

Materials:

Conductor: bare or tinned electrolytic copper wires, annealed, stranding class 5.

Insulation: thermosetting ethylene propylene rubber compound (EPR)

Textile Braid: braid of polyamide.

Coverage: thermosetting rubber compound

Specifications:

Identification of conductors: black numbered or color veins (on request).

Applicable Standards: NBR 9655

Packaging: Coil


DOWNLOAD PDF

Properties:

Working temperature: thermal stability up to 90 °C

Excellent resistance to ozone, weathering and water.

UV Resistance

Good resistance to oils

Good flexibility

Flame resistant

SO-M


Used for mobile installations, cranes and control pendants with 750V of Voltage.

Materials:

Conductor: bare or tinned electrolytic copper wires, annealed, stranding class 5.

Insulation: thermosetting ethylene propylene rubber compound (EPR)

Separator: Braided cotton yarns.

Coverage: thermosetting rubber compound

Specifications:

Identification of conductors: black numbered or color veins (on request).

Applicable Standards: NBR 9372

Packaging: Coil


DOWNLOAD PDF

Properties:

Working temperature: thermal stability up to 90 °C.

Excellent resistance to ozone, weathering and water

UV Resistance

Good resistance to oils

Good flexibility

Flame resistant

SHDM 3 KV-25KV


Applications in connections of heavy mobile equipment, metallurgy and port cranes.

Specifications:

SHDM – Three phase conductor cable, radial field, with individual or group shielding and 3 grounding or protection conductors in the vein intrinsic.

Applicable Standards: NBR 9375. Conditioning: Reel.

Materials:

Conductor: Bare or tinned copper wires, soft hardening. Stranding class 5

Shielding of the conductor: Semi-conducting textile tape.

Insulation: Thermo-fixed compound made of Ethylene-Propylene Rubber EPR 90°C.

Insulation Shielding: Semi-conducting textile tape.

Individual Insulation Shielding: Tinned copper braid.

Textile Tying.

Internal Cover: Thermo-fixed compound made of rubber 90°C.

Textile braid: Textile Tying.

Coverage: Thermo-fixed compound made of rubber 90°C.


DOWNLOAD PDF

Properties:

Work temperature: thermal stability up to 90°C.

Excellent resistance to ozone, the weather and water.

UV ray resistance.

Good oil resistance.

Good flexibility.

Fire resistant.

Panflat Elevador 300V


his cable has been specially developed for constant movements in lift deployment .

Specifications:

Conductor identification: Black veins, numbered or color (upon inquiry)

Applicable Standards: NBR NM 280, NBR 6251, NBR NM-IEC 60332-1

Materials:

Conductor: Bare electrolytic copper wires, soft hardening. Stranding class 5

Insulation: Thermoplastic compound of polyvinyl chloride (PVC)

Pair Shielding: Aluminium polyester tape 100% coverage with tinned drain cable 0.5mm.

Coverage:Thermoplastic compound of polyvinyl chloride. (PVC)


DOWNLOAD PDF

Properties:

Work temperature: Thermal stability up to 70 ° C

Fire resistance.

Water Resistance

Good oil resistance

Curvature radius:: 10x the cable height.

Shielded pair with 120 ohms impendance and VP - propagation speed> 65%

Maximum operation speed up to 4.0 m / s

Panmóvel (panmobile)


Specially designed for constant movement such as Cable carriers, cranes and machine parts in motion with 500V of Voltage.

Materials:

Unshielded Cables:

Conductor: bare electrolytic copper wires, annealed, stranding class 5.

Insulation: thermoplastic polyvinyl chloride compound (PVC)

Coverage: thermoplastic polyvinyl chloride compound (PVC) or polyurethane (TPU)

Shielded Cables:

Conductor: bare electrolytic copper wires, annealed, stranding class 5.

Insulation: thermoplastic polyvinyl chloride compound (PVC)

Internal Cover: thermoplastic polyvinyl chloride compound (PVC)

Shielding: bare copper wires braid.

Coverage: thermoplastic polyvinyl chloride compound (PVC) or polyurethane (TPU)

Specifications:

Identification of conductors: black numbered or colored veins (on request).

Applicable Standards: EPAN 21 (Pan Electric)


DOWNLOAD PDF

Properties:

PVC cover:

Working temperature: thermal stability up to 70 °C

Flame resistant

Moderate resistance to acids and bases

Good resistance to oils

Bend radius: 10 times the outer diameter of the cable

TPU Cover:

Working temperature: thermal stability up to 70 °C

High resistance to mineral oils

Water resistance to hydrolysis and fungal growth

High mechanical abrasion resistance

Bend radius: 10 times the outer diameter of the cable.

Panflat (flat cables)


Specially designed for constant movement equipment such as cranes and machine parts in motion.

Materials:

Conductor: bare or tinned electrolytic copper wires, annealed, stranding class 5.

Insulation: thermoplastic polyvinyl chloride compound (PVC)

Coverage: thermoplastic polyvinyl chloride compound (PVC)

Specifications:

Identification of conductors: black numbered or color veins (on request).

Applicable Standards: EPAN 22 (Pan Electric)

Packaging: Coils


DOWNLOAD PDF

Properties:

Working temperature: thermal stability 70 °C.

Bending radius of cable: up to 10 times the thickness of the complete cable

Isolation voltage: 300/500V in sections of 0.3 to 1.0 mm ² and 450/750V in sections of 1.5 to 25mm².

Panmobile Silicone


Specially developed for high and low temperatures, constant motion and the use in cable carriers, cranes and machine parts in motion with 750V of Voltage.

Unshielded Cables:

Conductor: bare electrolytic copper wires, annealed, stranding class 5.

Insulation: cross-linked silicone rubber for 200/300 °C

Coverage: special cross-linked silicone rubber for 200/300 °C

Shielded Cables:

Conductor: bare electrolytic copper wires, annealed, stranding class 5.

Insulation: cross-linked silicone rubber for 200/300 °C

Inside cover: cross-linked silicone rubber for 200/300 °C

Shielding: bare copper wires braid.

Coverage: cross-linked silicone rubber for 200/300 °C

Specifications:

Identification of conductors: white, numbered or colored veins (upon request).

Applicable Standards: EPAN 23 (Pan Electric)


DOWNLOAD PDF

Properties:

Working temperature: thermal stability up to 200/300 °C.

Flexible temperature

Moderate resistance to acids and bases

Good resistance to oils