NAVAL CABLES

In 2008, our line of marine cables (Instrumentation and Power) achieved Type Approval certification, by American Bureau Shipping - ABS. In the process, the compliance of all specific normative requirements for each cable line was verified, by conducting electrical, mechanical and chemical tests, in addition to the specific audit in our facilities for the analysis of processes, procedures and equipment. This certification guarantees reliability and safety, proving Pan Electric's efficiency and total commitment in yet another important field.

Pannav IA

IA – ARMED INSTRUMENTATION

Constructive Data | Standard IEC 60092-376

1 Conductor: Tinned Copper | IEC 60228 class 5

2 Insulation: HF90 | IEC 60092-360

3 Internal Cover: SHF1 | IEC 60092-360.

5 Frame: braid of galvanized steel wires or tinned copper with coverage> 90%.

6 Coverage: SHF1 or SHF2| IEC 60092-360

Construction: concentric conductors, pairs, triads or blocks.


Additional Features:
Halogen Free - Halogen Free - IEC 60754-1 and 2 and IEC 60684-2
Flame Retardant - Flame Retardant- IEC 60332-1 and IEC 60332-3-22cat-A
Low smoke emission - Low smoke - IEC 61034-1 and 2
Fire resistant - Fire resistant - IEC 60331-11 E 21 (optional)


DOWNLOAD PDF

Technical Details:

Application: fixed installations

Section Range: 0.5 to 2.5 mm2

Maximum temperature at conductor: 90 ºC

Marking: PAN ELECTRIC PANNAV IA, section, temperature, voltage, IEC 60332-3-22 cat A, year of manufacture.

Pannav PNB

PNB - NORMAL POWER SHIELDED

Constructive Data | Standard IEC 60092-353

1 Conductor: Tinned Copper | IEC 60228 class 5

2 Insulation: HF90 | IEC 60092-360.

3 Covering: SHF1 | IEC 60092-360.

4 Frame/Shielding: braid of galvanized steel wires or tinned copper with coverage> 90%.

5 Cover: Thermoplastic compound SHF1 or SHF2 IEC 60092-360.

Construction: single cable or concentric conductors with inner frame.


Additional Features:
Halogen Free - Halogen Free - IEC 60754-1 and 2 and IEC 60684-2
Flame Retardant - Flame Retardant - IEC 60332-1 and IEC 60332-3-22 cat-A
Low smoke emission - Low smoke - IEC 61034-1 and 2
Fire resistant - Fire resistant - IEC 60331-11 E 21 (optional)


DOWNLOAD PDF

Technical Details:

Application: fixed installations

Section Range: 1.0 to 500 mm2

Maximum temperature at conductor: 90 ºC

Marking: PAN ELECTRIC PANNAV PNB, section, temperature, voltage, IEC 60332-3-22 cat A, year of manufacture.

Pannav PN

PN - STANDARD POWER

Constructive Data | Standard IEC 60092-353

1 Conductor: Tinned Copper | IEC 60228 class 5

2 Insulation: HF90 | IEC 60092-360.

3 Covering: SHF1 or SHF2 | IEC 60092-360.

Construction: single cable or concentric conductors.


Additional Features:
Halogen Free - Halogen Free - IEC 60754-1 and 2 and IEC 60684-2
Flame Retardant - Flame Retardant - IEC 60332-1 and IEC 60332-3-22 cat-A
Low smoke emission - Low smoke - IEC 61034-1 and 2
Fire resistant - Fire resistant - IEC 60331-11 E 21 (optional)


DOWNLOAD PDF

Technical Details:

Application: fixed installations

Section Range: 1.0 to 500 mm2

Maximum temperature at conductor: 90 ºC

Marking: PAN ELECTRIC PANNAV PN, section, temperature, voltage, IEC 60332-3-22 cat A, year of manufacture.

Pannav IBIA

IBIA - INSTRUMENTATION WITH INDIVIDUAL ARMED SHIELDING

Constructive Data | Standard IEC 60092-376

1 Conductor: Tinned Copper | IEC 60228 class 5

2 Insulation: HF90 | IEC 60092-360

3 Individual Shielding: aluminized polyester tape + tinned cable drain.

4 Internal Cover: SHF1 | IEC 60092-360.

5 Frame: braid of galvanized steel wires or tinned copper with coverage> 90%.

6 Coverage: SHF1 or SHF2| IEC 60092-360

Construction: pairs, triads or blocks.

Additional Features:
Halogen Free - Halogen Free - IEC 60754-1 and 2 and IEC 60684-2
Flame Retardant - Flame Retardant - IEC 60332-1 and IEC 60332-3-22 cat-A
Low smoke emission - Low smoke - IEC 61034-1 and 2
Fire resistant - Fire resistant - IEC 60331-11 E 21 (optional)


DOWNLOAD PDF

Technical Details:

Application: fixed installations

Section Range: 0.5 to 2.5 mm2

Maximum temperature at conductor: 90 ºC

Marking: PAN ELECTRIC PANNAV IBIA, section, temperature, voltage, IEC 60332-3-22 cat A, year of manufacture.

Pannav IBCA

IBCA – INSTRUMENTATION WITH ARMED COLLECTIVE SHIELDING

Constructive Data | Standard IEC 60092-376

1 Conductor: Tinned Copper | IEC 60228 class 5

2 Insulation: HF90 | IEC 60092-360

3 Collective Shielding: aluminized polyester tape + tinned cable drain.

4 Internal Cover: SHF1 | IEC 60092-360.

5 Frame: braid of galvanized steel wires or tinned copper with coverage> 90%.

6 Coverage: SHF1 or SHF2 | IEC 60092-360

Construction: concentric conductors, pairs, triads or blocks.

Additional Features:
Halogen Free - Halogen Free - IEC 60754-1 and 2 and IEC 60684-2
Flame Retardant - Flame Retardant - IEC 60332-1 and IEC 60332-3-22 cat-A
Low smoke emission - Low smoke - IEC 61034-1 and 2
Fire resistant - Fire resistant - IEC 60331-11 E 21 (optional)

DOWNLOAD PDF

Technical Details:

Application: fixed installations

Section Range: 0.5 to 2.5 mm2

Maximum temperature at conductor: 90 ºC

Marking: PAN ELECTRIC PANNAV IBCA, section, temperature, voltage, IEC 60332-3-22 cat A, year of manufacture.

Pannav IBICA

IBICA - INSTRUMENTATION WITH ARMED INDIVIDUAL AND COLLECTIVE SHIELDING

Constructive Data | Standard IEC 60092-376

1 Conductor: Tinned Copper | IEC 60228 class 5

2 Insulation: HF90 | IEC 60092-360

3 Individual Shielding: aluminized polyester tape + tinned cable drain.

4 Collective Shielding: aluminized polyester tape + tinned cable drain.

5 Internal Cover: SHF1 | IEC 60092-360.

6 Frame: braid of galvanized steel wires or tinned copper with coverage> 90%.

7 Coverage: SHF1or SHF2 | IEC 60092-360

Construction: pairs, triads or blocks.

Additional Features:
Halogen Free - Halogen Free - IEC 60754-1 and 2 and IEC 60684-2
Flame Retardant - Flame Retardant - IEC 60332-1 and IEC 60332-3-22 cat-A
Low smoke emission - Low smoke - IEC 61034-1 and 2
Fire resistant - Fire resistant - IEC 60331-11 E 21 (optional)

DOWNLOAD PDF

Technical Details:

Application: fixed installations

Section Range: 0.5 to 2.5 mm2

Maximum temperature at conductor: 90 ºC

Marking: PAN ELECTRIC PANNAV IBICA, section, temperature, voltage, IEC 60332 - 3-22 cat A, year of manufacture.

Pannav IBC

IBC - INSTRUMENTATION WITH COLLECTIVE SHIELDING

Constructive Data | Standard IEC 60092-376

1 Conductor: Tinned Copper | IEC 60228 class 5

2 Insulation: HF90 | IEC 60092-360

3 Collective Shielding: aluminized polyester tape + tinned cable drain.

4Coverage: SHF1 or SHF2 | IEC 60092-360.

Construction: concentric conductors, pairs, triads or blocks.

Additional Features:
Halogen Free - Halogen Free - IEC 60754-1 and 2 and IEC 60684-2
Flame Retardant - Flame Retardant - IEC 60332-1 and IEC 60332-3-22 cat-A
Low smoke emission - Low smoke - IEC 61034-1 and 2
Fire resistant - Fire resistant - IEC 60331-11 E 21 (optional)

DOWNLOAD PDF

Technical Details:

Application: fixed installations

Section Range: 0.5 to 2.5 mm2

Maximum temperature at conductor: 90 ºC

Marking: PAN ELECTRIC PANNAV IBC, section, temperature, voltage, IEC 60332 - 3-22 cat A, year of manufacture.

Pannav IBIC

IBIC - INSTRUMENTATION WITH INDIVIDUAL AND COLLECTIVE SHIELDING

Constructive Data | Standard IEC 60092-376

1 Conductor: Tinned Copper | IEC 60228 class 5

2 Insulation: HF90 | IEC 60092-360

3 Individual Shielding: aluminized polyester tape + tinned cable drain.

4 Collective Shielding: aluminized polyester tape + tinned cable drain.

5 Coverage: SHF1 or SHF2 | IEC 60092-360.

Construction: pairs, triads or blocks.

Additional Features:
Halogen Free - Halogen Free - IEC 60754-1 and 2 and IEC 60684-2
Flame Retardant - Flame Retardant - IEC 60332-1 and IEC 60332-3-22 cat-A
Low smoke emission - Low smoke - IEC 61034-1 and 2
Fire resistant - Fire resistant - IEC 60331-11 E 21 (optional)

DOWNLOAD PDF

Technical Details:

Application: fixed installations

Section Range: 0.5 to 2.5 mm2

Maximum temperature at conductor: 90 ºC

Marking: PAN ELECTRIC PANNAV IBIC, section, temperature, voltage, IEC 60332 - 3-22 cat A, year of manufacture.

Pannav IBI

IBI - INSTRUMENTATION WITH INDIVIDUAL SHIELDING

Constructive Data | Standard IEC 60092-376

1 Conductor: Tinned Copper | IEC 60228 class 5

2 Insulation: HF90 | IEC 60092-360

3 Individual Shielding: aluminized polyester tape + tinned cable drain.

4 Coverage: SHF1 or SHF2 | IEC 60092-360. Construction: pairs, triads or blocks.

Additional Features:
Halogen Free - Halogen Free - IEC 60754-1 and 2 and IEC 60684-2
Flame Retardant - Flame Retardant - IEC 60332-1 and IEC 60332-3-22 cat-A
Low smoke emission - Low smoke - IEC 61034-1 and 2
Fire resistant - Fire resistant - IEC 60331-11 E 21 (optional)

DOWNLOAD PDF

Technical Details:

Application: fixed installations

Section Range: 0.5 to 2.5 mm2

Maximum temperature at conductor: 90 ºC

Marking: PAN ELECTRIC PANNAV IBI, section, temperature, voltage, IEC 60332 - 3-22 cat A, year of manufacture.

Pannav IN

IN - STANDARD INSTRUMENTATION

Constructive Data | Standard IEC 60092-376

1 Conductor: Tinned Copper | IEC 60228 class 5

2 Insulation: HF90 | IEC 60092-360

3 Cover: SHF1 or SHF2 | IEC 60092-360

Construction: Concentric conductors, pairs, triads or blocks


Additional Features:
Halogen Free - Halogen Free - IEC 60754-1 and 2 and IEC 60684-2
Flame Retardant - Flame Retardant - IEC 60332-1 and IEC 60332-3-22 cat-A
Low smoke emission - Low smoke - IEC 61034-1 and 2
Fire resistant - Fire resistant - IEC 60331-11 E 21 (optional)


DOWNLOAD PDF

Technical Details:

Application: fixed installations

Section Range: 0.5 to 2.5 mm2

Maximum temperature at conductor: 90 ºC

Marking: PAN ELECTRIC PANNAV IN, section, temperature, voltage, IEC 60332 - 3-22 cat A, year of manufacture.